อุปกรณ์บัลลาสท์ Electronic Ballast
Lamp
|
1x18W T8
|
Nominal Input Power
|
18 Watt
|
Nominal Input Current
|
0.080 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AV 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.95
|
Total Hamonics Distortion (THDI)
|
<27%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.95
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
Over Cuppent Sustenable Circuit
|
Lamp Starting
|
Instant Start
|
Main Transient Over Voltage
|
IEC 60929, 6100-4-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x150x25 mm. For 18 W
|
Lamp
|
1x32W T8
|
Nominal Input Power
|
32 Watt
|
Nominal Input Current
|
0.15 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AV 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.95
|
Total Hamonics Distortion (THDI)
|
<28%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.95
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
Over Cuppent Sustenable Circuit
|
Lamp Starting
|
Preheat Starting
|
Main Transient Over Voltage
|
IEC 60929, 6100-4-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x173x25 mm. For 32 W
|
Lamp
|
1x36W T8
|
Nominal Input Power
|
36 Watt
|
Nominal Input Current
|
0.165 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AV 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.95
|
Total Hamonics Distortion (THDI)
|
<27%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.95
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
Over Cuppent Sustenable Circuit
|
Lamp Starting
|
Preheat Starting
|
Main Transient Over Voltage
|
IEC 60929, 6100-4-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x150x25 mm. For 36 W
|
Lamp
|
1x14W T5
|
Nominal Input Power
|
14 Watt
|
Nominal Input Current
|
0.075 AMP
|
Watt Loss Ballast
|
2 Watt
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
<0.9
|
Total Hamonics Distortion (THDI)
|
<30%
|
Input Current Hamonics
|
-
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<2.1
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Preheat Starting
|
Main Transient Over Voltage
|
IEC 60929, 6100-4-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x173x25 mm.
|
Lamp
|
1x21W T5
|
Nominal Input Power
|
21 Watt
|
Nominal Input Current
|
0.105 AMP
|
Watt Loss Ballast
|
2 Watt
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
<0.9
|
Total Hamonics Distortion (THDI)
|
<30%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<2.1
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Preheat Starting
|
Main Transient Over Voltage
|
IEC 60929, 6100-4-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x173x25 mm.
|
Lamp
|
1x28W T5
|
Nominal Input Power
|
28 Watt
|
Nominal Input Current
|
0.135 AMP
|
Watt Loss Ballast
|
2 Watt
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
<0.9
|
Total Hamonics Distortion (THDI)
|
<30%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<2.1
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Preheat Starting
|
Main Transient Over Voltage
|
IEC 60929, 6100-4-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x173x25 mm.
|
Lamp
|
1x28W T5 G13
|
|
1x20W T12 cap G13
|
|
1x18 TC-L cap 2G11
|
Nominal Input Power
|
18 Watt
|
Nominal Input Current
|
0.080 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AC 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.99
|
Total Hamonics Distortion (THDI)
|
<8%
|
Input Current Hamonics
|
Acc. to IEC 61000-3-2
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.65
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
Automatic Safety Stop
|
Lamp Starting
|
Instant Starting
|
Main Transient Over Voltage
|
TIS 1506-2541
|
|
IEC 60929,6100-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Performance Conformity
|
TIS 1506-2541, IEC 60929
|
Dimension [WxLxH]
|
30x310x25 mm.
|
Lamp
|
1x36W T8 G13
|
|
1x40W T12 cap G13
|
|
1x36 TC-L cap 2G11
|
Nominal Input Power
|
36 Watt
|
Nominal Input Current
|
0.16 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AC 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.99
|
Total Hamonics Distortion (THDI)
|
<8%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.65
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Automatic Safety Stop
|
Main Transient Over Voltage
|
TIS 1506-2541
|
|
IEC 60929,6100-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
30x310x25 mm.
|
Lamp
|
1x18W T8 cap G13
|
|
1x20W T12 cap G13
|
|
1x18 TC-L cap 2G11
|
Nominal Input Power
|
18 Watt
|
Nominal Input Current
|
0.085 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AC 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.99
|
Total Hamonics Distortion (THDI)
|
<10%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.70
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Instant Start
|
Main Transient Over Voltage
|
TIS 1506-2541
|
|
IEC 60929,6100-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x173x25 mm.
|
Lamp
|
1x36W T8 cap G13
|
|
1x36W T12 cap G13
|
|
1x36W TC-L cap 2G11
|
Nominal Input Power
|
36 Watt
|
Nominal Input Current
|
0.16 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AC 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.99
|
Total Hamonics Distortion (THDI)
|
<10%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.80
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Instant Start
|
Main Transient Over Voltage
|
TIS 1506-2541
|
|
IEC 60929,6100-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
34x173x25 mm.
|
Lamp
|
1x54W T5
|
Nominal Input Power
|
54 Watt
|
Nominal Input Current
|
0.24 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AC 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.99
|
Total Hamonics Distortion (THDI)
|
<10%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.70
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Instant Start
|
Main Transient Over Voltage
|
IEC 60929,6100-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
40x222x30 mm.
|
Lamp
|
1x55W T5
|
Nominal Input Power
|
55 Watt
|
Nominal Input Current
|
0.26 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AC 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.99
|
Total Hamonics Distortion (THDI)
|
<10%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.70
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Instant Start
|
Main Transient Over Voltage
|
IEC 60929,6100-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Dimension [WxLxH]
|
40x222x30 mm.
|
Lamp
|
2x36W T8 cap G13
|
|
2x40W T12 cap G13
|
|
2x36W TC-L cap 2G11
|
Nominal Input Power
|
68 Watt
|
Nominal Input Current
|
0.32 AMP
|
Rated Input Voltage and Frequency
|
220 Volts AC 50 Hz
|
Operating Input Voltage Range
|
160 To 260 Volts AC
|
Power Factor
|
0.99
|
Total Hamonics Distortion (THDI)
|
<12%
|
Input Current Hamonics
|
ANSI Standard C 82.11
|
Max.Alowable Case Temperature (TC)
|
90 C
|
Ambient Operating Temperature (TA)
|
+5...+55 C
|
Environment Operating Humidity
|
0...95% RH (Non-Condensation)
|
Ballast Lumen Factor
|
0.95
|
Lamp Current Crest Factor
|
<1.70
|
Operating Frequency
|
50-70 kHz
|
Lamp Failure Protection
|
High Cument Durable Circuit
|
Lamp Starting
|
Instant Start
|
Main Transient Over Voltage
|
TIS 1506-2541
|
|
IEC 60929,6100-4, 6100-4-5
|
Safety
|
TIS 885-2532
|
|
IEC 61347-2-3
|
Electromagnatic Compatibility (EMC)
|
TIS 1955-2551
|
|
CISPR 15/EN 55015
|
Immunity
|
IEC 61547
|
Performance Conformity
|
TIS 1506-2541, IEC 60929
|
Dimension [WxLxH]
|
40x222x30 mm.
|
|