600 V CVV
2-48 CORES – POLYVINYL CHORIDE FLEXIBLE CONTROL CABLE
Construction
|
Reference Standard
|
1.Conductor : Bunched stranded annealed Copper
2.Insulation : Polyvinyl chloride (PVC), Black color with marking number on the surface of insulation
3.Filler : Polypropylene (Non-hygroscopic material)
4.Binding tape : Polyester tape and/or Spunbond tape
5.Sheath : Polyvinyl chloride (PVC), Black color
|
BCC’s standard
|
Classification
|
Maximum conductor temperature : 70oC
Maximum circuit voltage : 600 V
AC test voltage : 2,000 V
|
Application
|
For supervisory electrical equipment, station control circuits, outdoor, suitable installation in the dry or wet cable trenches.
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
2
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
39.0
|
50
|
สายไฟบางกอก
Bangkok cable
|
2
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
26.0
|
50
|
สายไฟบางกอก
Bangkok cable
|
2
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
19.5
|
50
|
สายไฟบางกอก
Bangkok cable
|
2
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
13.3
|
50
|
สายไฟบางกอก
Bangkok cable
|
2
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
7.98
|
50
|
สายไฟบางกอก
Bangkok cable
|
2
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
4.95
|
50
|
สายไฟบางกอก
Bangkok cable
|
2
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
3.30
|
50
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
3
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
8.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
3
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
8.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
3
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
8.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
3
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
9.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
3
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
10.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
3
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
12.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
3
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
15.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
4
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
8.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
4
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
9.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
4
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
9.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
4
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
10.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
4
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
11.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
4
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
14.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
4
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
16.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
5
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
9.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
5
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
9.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
5
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
10.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
5
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
11.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
5
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
13.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
5
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
15.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
5
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
18.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
6
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
9.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
6
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
10.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
6
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
11.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
6
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
11.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
6
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
14.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
6
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
16.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
6
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
19.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
7
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
9.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
7
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
10.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
7
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
11.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
7
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
11.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
7
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
14.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
7
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
16.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
7
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
19.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
8
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
10.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
8
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
11.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
8
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
11.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
8
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
13.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
8
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
15.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
8
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
18.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
8
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
21.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
9
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
11.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
9
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
12.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
9
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
13.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
9
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
14.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
9
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
16.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
9
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
19.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
9
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
23.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
10
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
12.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
10
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
13.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
10
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
14.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
10
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
15.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
10
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
17.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
10
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
21.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
10
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
25.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
11
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
12.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
11
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
13.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
11
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
14.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
11
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
15.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
11
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
18.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
11
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
21.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
11
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
26.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
12
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
12.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
12
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
13.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
12
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
14.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
12
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
15.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
12
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
18.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
12
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
21.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
12
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
26.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
13
|
0.5
|
0.21
|
0.92
|
0.6
|
1.2
|
13.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
13
|
0.75
|
0.21
|
1.13
|
0.6
|
1.2
|
14.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
13
|
1
|
0.21
|
1.31
|
0.6
|
1.2
|
15.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
13
|
1.5
|
0.26
|
1.58
|
0.6
|
1.2
|
16.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
13
|
2.5
|
0.26
|
2.04
|
0.7
|
1.2
|
19.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
13
|
4
|
0.31
|
2.59
|
0.8
|
1.2
|
22.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
13
|
6
|
0.31
|
3.60
|
0.8
|
1.4
|
28.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
14
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
13.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
14
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
14.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
14
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
15.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
14
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
16.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
14
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
19.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
14
|
4
|
0.31
|
2.59
|
0.8
|
1.4
|
22.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
14
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
28.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
15
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
14.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
15
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
15.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
15
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
15.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
15
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
17.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
15
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
20.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
15
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
24.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
15
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
29.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
16
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
14.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
16
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
15.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
16
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
15.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
16
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
17.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
16
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
20.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
16
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
24.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
16
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
29.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
17
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
15.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
17
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
15.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
17
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
16.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
17
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
18.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
17
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
21.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
17
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
26.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
17
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
31.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
18
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
14.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
18
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
15.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
18
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
16.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
18
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
18.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
18
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
21.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
18
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
26.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
18
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
32.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
19
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
14.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
19
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
15.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
19
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
16.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
19
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
18.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
19
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
21.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
19
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
26.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
19
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
31.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
20
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
15.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
20
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
16.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
20
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
17.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
20
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
17.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
20
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
19.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
20
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
22.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
20
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
27.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
21
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
15.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
21
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
16.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
21
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
17.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
21
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
19.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
21
|
2.5
|
0.26
|
2.04
|
0.7
|
1.4
|
22.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
21
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
27.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
21
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
32.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
22
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
16.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
22
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
17.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
22
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
18.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
22
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
19.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
22
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
24.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
22
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
28.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
22
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
34.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
23
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
16.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
23
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
17.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
23
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
18.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
23
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
19.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
23
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
24.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
23
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
28.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
23
|
6
|
0.31
|
3.60
|
0.8
|
1.8
|
34.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
24
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
17.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
24
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
18.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
24
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
19.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
24
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
21.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
24
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
26.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
24
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
30.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
24
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
37.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
25
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
17.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
25
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
18.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
25
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
19.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
25
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
21.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
25
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
26.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
25
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
31.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
25
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
38.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
26
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
17.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
26
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
18.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
26
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
19.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
26
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
21.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
26
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
26.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
26
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
31.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
26
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
38.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
27
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
17.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
27
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
18.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
27
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
19.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
27
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
21.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
27
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
26.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
27
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
31.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
27
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
38.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
28
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
18.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
28
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
19.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
28
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
20.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
28
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
22.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
28
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
27.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
28
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
32.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
28
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
39.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
29
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
18.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
29
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
19.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
29
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
20.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
29
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
22.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
29
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
27.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
29
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
32.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
29
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
39.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
30
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
18.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
30
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
19.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
30
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
20.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
30
|
1.5
|
0.26
|
1.58
|
0.6
|
1.4
|
22.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
30
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
27.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
30
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
32.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
30
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
39.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
31
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
18.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
31
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
20.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
31
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
21.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
31
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
23.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
31
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
28.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
31
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
33.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
31
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
41.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
32
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
18.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
32
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
20.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
32
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
21.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
32
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
23.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
32
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
28.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
32
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
33.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
32
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
41.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
33
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
18.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
33
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
20.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
33
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
21.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
33
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
23.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
33
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
28.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
33
|
4
|
0.31
|
2.59
|
0.8
|
1.8
|
33.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
33
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
41.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
34
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
19.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
34
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
20.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
34
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
22.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
34
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
24.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
34
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
29.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
34
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
35.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
34
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
42.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
35
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
19.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
35
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
20.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
35
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
22.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
35
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
24.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
35
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
29.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
35
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
35.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
35
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
42.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
36
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
19.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
36
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
20.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
36
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
22.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
36
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
24.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
36
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
29.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
36
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
35.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
36
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
42.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
37
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
19.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
37
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
20.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
37
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
22.0
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
37
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
24.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
37
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
29.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
37
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
35.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
37
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
42.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
38
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
20.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
38
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
21.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
38
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
22.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
38
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
25.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
38
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
30.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
38
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
37.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
38
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
44.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
39
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
20.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
39
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
21.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
39
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
22.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
39
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
25.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
39
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
30.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
39
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
37.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
39
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
44.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
40
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
20.0
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
40
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
21.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
40
|
1
|
0.21
|
1.31
|
0.6
|
1.4
|
22.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
40
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
25.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
40
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
30.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
40
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
37.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
40
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
44.5
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
41
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
20.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
41
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
22.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
41
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
24.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
41
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
26.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
41
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
31.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
41
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
38.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
41
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
46.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
42
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
20.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
42
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
22.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
42
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
24.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
42
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
26.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
42
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
31.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
42
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
38.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
42
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
46.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
43
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
20.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
43
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
22.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
43
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
24.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
43
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
26.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
43
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
31.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
43
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
38.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
43
|
6
|
0.31
|
3.60
|
0.8
|
2.2
|
46.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
44
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
21.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
44
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
23.0
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
44
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
25.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
44
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
27.5
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
44
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
33.0
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
44
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
40.0
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
44
|
6
|
0.31
|
3.60
|
0.8
|
2.6
|
49.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
45
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
21.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
45
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
23.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
45
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
25.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
45
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
28.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
45
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
33.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
45
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
40.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
45
|
6
|
0.31
|
3.60
|
0.8
|
2.6
|
50.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
46
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
21.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
46
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
23.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
46
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
25.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
46
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
28.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
46
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
33.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
46
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
40.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
46
|
6
|
0.31
|
3.60
|
0.8
|
2.6
|
50.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
47
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
21.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
47
|
0.75
|
0.21
|
1.13
|
0.6
|
1.4
|
23.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
47
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
25.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
47
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
28.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
47
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
33.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
47
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
40.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
47
|
6
|
0.31
|
3.60
|
0.8
|
2.6
|
50.0
|
3.30
|
Product Brand
|
Number of core
|
Conductor
|
Thickness of insulation screen
mm
(Nominal)
|
Thickness of insulation mm
(Nominal)
|
DC conductor resistance at 20oC
Ω/km
(Max.)
|
Insulation resistance at 20oC
MΩ/km
(Max.)
|
Cross-sectional area
mm2
|
No. of wires
(Min.)
|
Diameter
mm
(Approx.)
|
สายไฟบางกอก
Bangkok cable
|
48
|
0.5
|
0.21
|
0.92
|
0.6
|
1.4
|
21.5
|
39.0
|
สายไฟบางกอก
Bangkok cable
|
48
|
0.75
|
0.21
|
1.13
|
0.6
|
1.8
|
23.5
|
26.0
|
สายไฟบางกอก
Bangkok cable
|
48
|
1
|
0.21
|
1.31
|
0.6
|
1.8
|
25.5
|
19.5
|
สายไฟบางกอก
Bangkok cable
|
48
|
1.5
|
0.26
|
1.58
|
0.6
|
1.8
|
28.0
|
13.3
|
สายไฟบางกอก
Bangkok cable
|
48
|
2.5
|
0.26
|
2.04
|
0.7
|
1.8
|
33.5
|
7.98
|
สายไฟบางกอก
Bangkok cable
|
48
|
4
|
0.31
|
2.59
|
0.8
|
2.2
|
40.5
|
4.95
|
สายไฟบางกอก
Bangkok cable
|
48
|
6
|
0.31
|
3.60
|
0.8
|
2.6
|
50.0
|
3.30
|